WLAN-Status 21.11.2024 23:31:49
Access Points mit 11 bis 25 Sessions innerhalb der vergangenen 7 Tage
Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Hauptgebäude
Name: AP-Inv42-R1134 Hardware: AP310i Serial Number: 2037Y-1074500000 device unreachable probably powered off due to energy saving Last succ. Poll: 21.11.2024 22:09:48 Basic PwrUsage: 6100mW SavedEnergy: 31.127,54 Wh (since: 28.09.2022 22:14:01) IP: 172.19.174.202 eth0: 20:9e:f7:76:fa:b4 SW Version: 7.8.6.0-002R Home-Controller: ECA-UdL6 WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 10 / 23 / 23 |
| ||||||||||||||||||||||||
Connected to: Inv42-HG-1133b ge.1.44 Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Hauptgebäude ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
Name: AP-Inv42-R1152 Hardware: AP310i Serial Number: 2037Y-1384200000 device unreachable probably powered off due to energy saving Last succ. Poll: 21.11.2024 22:09:48 Basic PwrUsage: 6100mW SavedEnergy: 36.666,10 Wh (since: 06.10.2022 22:14:01) IP: 172.19.174.203 eth0: 20:9e:f7:77:39:02 SW Version: 7.8.6.0-002R Home-Controller: ECA-UdL6 WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 23 / 24 / 37 |
| ||||||||||||||||||||||||
Connected to: Inv42-HG-1133b ge.1.45 Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Hauptgebäude ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
Name: AP-Inv42-K51 Hardware: AP310i Serial Number: 2038Y-1395600000 device unreachable probably powered off due to energy saving Last succ. Poll: 21.11.2024 22:09:48 IP: 172.19.174.121 eth0: 20:9e:f7:77:32:72 SW Version: 7.8.6.0-002R Home-Controller: ECA-GZ WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 10 / 15 / 15 |
| ||||||||||||||||||||||||
Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Hauptgebäude ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
Name: AP-Inv42-R1147 Hardware: AP310i Serial Number: 2037Y-1057900000 device unreachable probably powered off due to energy saving Last succ. Poll: 21.11.2024 22:09:48 Basic PwrUsage: 6000mW SavedEnergy: 37.355,40 Wh (since: 14.09.2022 22:14:02) IP: 172.19.174.124 eth0: 20:9e:f7:76:f7:76 SW Version: 7.8.6.0-002R Home-Controller: ECA-UdL6 WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 23 / 23 / 28 |
| ||||||||||||||||||||||||
Connected to: Inv42-HG-1133b ge.1.46 Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Hauptgebäude ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
Name: AP-Inv42-R1038 Hardware: AP310i Serial Number: 2201Y-1167000000 device unreachable probably powered off due to energy saving Last succ. Poll: 21.11.2024 22:09:48 Basic PwrUsage: 5700mW SavedEnergy: 33.823,81 Wh (since: 14.09.2022 22:14:02) IP: 172.19.174.113 eth0: b0:27:cf:cc:d8:57 SW Version: 7.8.6.0-002R Home-Controller: ECA-UdL6 WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 5 / 19 / 21 |
| ||||||||||||||||||||||||
Connected to: Inv42-K42 ge.2.48 Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Hauptgebäude ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
Name: AP-Inv42-R1044 Hardware: AP310i Serial Number: 2037Y-1060600000 Uptime: 17:41:41 h Last succ. Poll: 21.11.2024 23:30:24 Basic PwrUsage: 5800mW SavedEnergy: 6.429,57 Wh (since: 02.10.2022 21:29:02) IP: 172.19.174.126 eth0: 20:9e:f7:76:f7:fd eth0 In Errors: 0 SW Version: 7.8.6.0-002R Home-Controller: ECA-UdL6 Active/Backup-Ctrl: ECA-UdL6 / ECA-GZ Poll-Timeout: 3s R1 5.0 GHzCh: 36 (5180 MHz) Pwr-Lvl : 10 dBm Radio-Type: IEEE 802.11ax W.: 40 MHz Max-W: 40 MHz Bond.: Yes DCS: monitor Ch Busy Ø: 2% Rx Frames Ø: 0% AP Tx Ø: 1% MBR: 6 MBit/s Avg Noise: -91dBm Beacon Interval: 100ms R2 2.4 GHzCh: 13 (2472 MHz) Pwr-Lvl : 12 dBm Radio-Type: IEEE 802.11ax W.: 20 MHz Max-W: 20 MHz Bond.: No DCS: monitor Ch Busy Ø: 5% Rx Frames Ø: 0% AP Tx Ø: 1% MBR: 6 MBit/s Avg Noise: -98dBm Beacon Interval: 100ms WLAN-Sessions: 1 (R1: 1) Accs: HU: 1 5.0ac: 1 valid/invalid/unknown IPs: 1 / 0 / 0 auth/not auth Clients: 1 / - Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 14 / 14 / 15 |
| ||||||||||||||||||||||||
Connected to: Inv42-K42 ge.2.47 Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Hauptgebäude ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A |
Hilfe - Aktualisierungsintervall: 5 Minuten
Version 12.5.4, syj, 05.11.2024
Datenerhebung: 21.11.2024 23:29:01 Erzeugt: 21.11.2024 23:31:49 PID 1269083