WLAN-Status 22.11.2024 00:11:46
Access Points mit 11 bis 25 Sessions innerhalb der vergangenen 24 Stunden
Berlin-Mitte, Campus Nord > Invalidenstr. 42
Name: AP-Inv42-R1044 Hardware: AP310i Serial Number: 2037Y-1060600000 Uptime: 18:22:41 h Last succ. Poll: 22.11.2024 00:10:24 Basic PwrUsage: 5800mW SavedEnergy: 6.429,57 Wh (since: 02.10.2022 21:29:02) IP: 172.19.174.126 eth0: 20:9e:f7:76:f7:fd eth0 In Errors: 0 SW Version: 7.8.6.0-002R Home-Controller: ECA-UdL6 Active/Backup-Ctrl: ECA-UdL6 / ECA-GZ Poll-Timeout: 3s R1 5.0 GHzCh: 36 (5180 MHz) Pwr-Lvl : 10 dBm Radio-Type: IEEE 802.11ax W.: 40 MHz Max-W: 40 MHz Bond.: Yes DCS: monitor Ch Busy Ø: 3% Rx Frames Ø: 0% AP Tx Ø: 1% MBR: 6 MBit/s Avg Noise: -91dBm Beacon Interval: 100ms R2 2.4 GHzCh: 13 (2472 MHz) Pwr-Lvl : 12 dBm Radio-Type: IEEE 802.11ax W.: 20 MHz Max-W: 20 MHz Bond.: No DCS: monitor Ch Busy Ø: 7% Rx Frames Ø: 1% AP Tx Ø: 1% MBR: 6 MBit/s Avg Noise: -99dBm Beacon Interval: 100ms WLAN-Sessions: 1 (R1: 1) Accs: HU: 1 5.0ac: 1 valid/invalid/unknown IPs: 1 / 0 / 0 auth/not auth Clients: 1 / - Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 14 / 14 / 15 |
| ||||||||||||||||||||||||
Connected to: Inv42-K42 ge.2.47 Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Hauptgebäude ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
Name: AP-Inv42-Neubau-K07 Hardware: AP3805i Serial Number: 16424752085M0000 device unreachable probably powered off due to energy saving Last succ. Poll: 21.11.2024 21:09:12 Basic PwrUsage: 3200mW SavedEnergy: 22.211,22 Wh (since: 24.08.2022 21:14:01) IP: 172.19.174.183 eth0: d8:84:66:75:75:00 SW Version: 09.21.20.0001 Home-Controller: GZ WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 13 / 19 / 36 |
| ||||||||||||||||||||||||
ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
Name: AP-Inv42-Ostbau-2.103 Hardware: AP3915i Serial Number: 1918Y-1072100000 device unreachable probably powered off due to energy saving Last succ. Poll: 21.11.2024 22:09:48 Basic PwrUsage: 5600mW SavedEnergy: 37.373,15 Wh (since: 25.08.2022 01:49:01) IP: 172.19.174.106 eth0: dc:b8:08:6c:e8:40 SW Version: 10.51.23.0003 Home-Controller: ECA-UdL6 WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 14 / 17 / 21 |
| ||||||||||||||||||||||||
Connected to: Inv42-Ostbau-2002 ge.1.47 Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Ostbau ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
Name: AP-Inv42-R1023A Hardware: AP310i Serial Number: 2038Y-1407000000 device unreachable probably powered off due to energy saving Last succ. Poll: 21.11.2024 22:09:48 Basic PwrUsage: 6200mW SavedEnergy: 37.350,23 Wh (since: 14.09.2022 22:14:02) IP: 172.19.174.123 eth0: 20:9e:f7:77:34:ac SW Version: 7.8.6.0-002R Home-Controller: ECA-GZ WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 11 / 29 / 29 |
| ||||||||||||||||||||||||
Connected to: Inv42-K017 ge.2.22 Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Hauptgebäude ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
Name: AP-Inv42-R1147 Hardware: AP310i Serial Number: 2037Y-1057900000 device unreachable probably powered off due to energy saving Last succ. Poll: 21.11.2024 22:09:48 Basic PwrUsage: 6000mW SavedEnergy: 37.359,40 Wh (since: 14.09.2022 22:14:02) IP: 172.19.174.124 eth0: 20:9e:f7:76:f7:76 SW Version: 7.8.6.0-002R Home-Controller: ECA-UdL6 WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 23 / 23 / 28 |
| ||||||||||||||||||||||||
Connected to: Inv42-HG-1133b ge.1.46 Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Hauptgebäude ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
Name: AP-Inv42-Nordbau-3009 Hardware: AP310i Serial Number: 2037Y-1060400000 device unreachable probably powered off due to energy saving Last succ. Poll: 21.11.2024 22:09:48 Basic PwrUsage: 5900mW SavedEnergy: 36.378,56 Wh (since: 14.09.2022 23:14:02) IP: 172.19.174.200 eth0: 20:9e:f7:76:f7:f3 SW Version: 7.8.6.0-002R Home-Controller: ECA-UdL6 WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 17 / 184 / 198 |
| ||||||||||||||||||||||||
Controller Site: Invalidenstr Connected to: Inv42-Nordbau-3024 e 1/1/2 Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Nordbau ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
Name: AP-Inv42-R1131 Hardware: AP310i Serial Number: 2037Y-1065200000 device unreachable probably powered off due to energy saving Last succ. Poll: 21.11.2024 22:09:48 Basic PwrUsage: 8600mW SavedEnergy: 35.034,16 Wh (since: 28.09.2022 22:14:01) IP: 172.19.174.201 eth0: 20:9e:f7:76:f8:e3 SW Version: 7.8.6.0-002R Home-Controller: ECA-GZ WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 12 / 29 / 29 |
| ||||||||||||||||||||||||
Connected to: Inv42-HG-1133b ge.1.47 Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Hauptgebäude ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
Name: AP-Inv42-R1152 Hardware: AP310i Serial Number: 2037Y-1384200000 device unreachable probably powered off due to energy saving Last succ. Poll: 21.11.2024 22:09:48 Basic PwrUsage: 6100mW SavedEnergy: 36.670,17 Wh (since: 06.10.2022 22:14:01) IP: 172.19.174.203 eth0: 20:9e:f7:77:39:02 SW Version: 7.8.6.0-002R Home-Controller: ECA-UdL6 WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 23 / 24 / 37 |
| ||||||||||||||||||||||||
Connected to: Inv42-HG-1133b ge.1.45 Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Hauptgebäude ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A |
Hilfe - Aktualisierungsintervall: 5 Minuten
Version 12.5.4, syj, 05.11.2024
Datenerhebung: 22.11.2024 00:09:02 Erzeugt: 22.11.2024 00:11:46 PID 1279826