
WLAN-Status 09.05.2025 07:36:25
Access Points mit mehr als 50 Sessions innerhalb der vergangenen 4 Wochen
Berlin-Mitte, Campus Nord > Invalidenstr. 42
Name: AP-Inv42-Neubau-312 Hardware: AP310i Serial Number: 2038Y-1364000000 Uptime: 01:46:11 h Last succ. Poll: 09.05.2025 07:34:15 Basic PwrUsage: 5600mW SavedEnergy: 37.569,36 Wh (since: 25.08.2022 00:14:02) IP: 172.19.174.177 eth0: 20:9e:f7:77:2c:46 eth0 In Errors: 0 SW Version: 7.8.6.0-002R Home-Controller: ECA-UdL6 Active/Backup-Ctrl: ECA-UdL6 / ECA-GZ Poll-Timeout: 3s R1 5.0 GHzCh: 100 (5500 MHz) Pwr-Lvl : 18 dBm Radio-Type: IEEE 802.11ax W.: 40 MHz Max-W: 40 MHz Bond.: Yes DCS: monitor Ch Busy Ø: 3% Rx Frames Ø: 1% AP Tx Ø: 1% MBR: 6 MBit/s Avg Noise: -90dBm Beacon Interval: 100ms R2 2.4 GHzCh: 9 (2452 MHz) Pwr-Lvl : 12 dBm Radio-Type: IEEE 802.11ax W.: 20 MHz Max-W: 20 MHz Bond.: No DCS: monitor Ch Busy Ø: 6% Rx Frames Ø: 1% AP Tx Ø: 2% MBR: 6 MBit/s Avg Noise: -100dBm Beacon Interval: 100ms WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 2 / 58 / 58 |
| ||||||||||||||||||||||||
![]()
Connected to: ICX-Inv42-Neub-211 e 1/1/45 Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Mittelbau IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
Name: AP-Inv42-Nordbau-3009 Hardware: AP310i Serial Number: 2037Y-1060400000 Uptime: 01:46:57 h Last succ. Poll: 09.05.2025 07:34:15 Basic PwrUsage: 6000mW SavedEnergy: 44.265,90 Wh (since: 14.09.2022 23:14:02) IP: 172.19.174.200 eth0: 20:9e:f7:76:f7:f3 eth0 In Errors: 0 SW Version: 7.8.6.0-002R Home-Controller: ECA-UdL6 Active/Backup-Ctrl: ECA-UdL6 / ECA-GZ Poll-Timeout: 3s R1 5.0 GHzCh: 132 (5660 MHz) Pwr-Lvl : 18 dBm Radio-Type: IEEE 802.11ax W.: 40 MHz Max-W: 40 MHz Bond.: Yes DCS: monitor Ch Busy Ø: 1% Rx Frames Ø: 0% AP Tx Ø: 1% MBR: 6 MBit/s Avg Noise: -92dBm Beacon Interval: 100ms R2 2.4 GHzCh: 5 (2432 MHz) Pwr-Lvl : 12 dBm Radio-Type: IEEE 802.11ax W.: 20 MHz Max-W: 20 MHz Bond.: No DCS: monitor Ch Busy Ø: 28% Rx Frames Ø: 22% AP Tx Ø: 1% MBR: 6 MBit/s Avg Noise: -98dBm Beacon Interval: 100ms WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 2 / 86 / 123 |
| ||||||||||||||||||||||||
![]()
Controller Site: Invalidenstr Connected to: ICX-Inv42-Nordbau-3024 e 1/1/2 Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Nordbau IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
Name: AP-Inv42-Nordbau-HS10-Beamer Hardware: AP3825i Serial Number: 16360743085M0000 Uptime: 01:46:03 h Last succ. Poll: 09.05.2025 07:34:15 Basic PwrUsage: 6600mW SavedEnergy: 47.782,75 Wh (since: 25.08.2022 01:49:01) IP: 172.19.174.225 eth0: d8:84:66:74:ee:5f eth0 In Errors: 0 SW Version: 09.21.20.0001 Home-Controller: GZ Active/Backup-Ctrl: GZ / UdL6 Poll-Timeout: 4s R1 5.0 GHzCh: 56-1 (5280 MHz) Pwr-Lvl (8 ≤ 16): 16 dBm Radio-Type: IEEE 802.11ac W.: 40 MHz Max-W: 40 MHz Bond.: Yes Ch-Plan: All Channels DCS: active DCS Threshold: -84 dBm Ch Busy Ø: 0% Rx Frames Ø: 0% AP Tx Ø: 0% MBR: 12 MBit/s Avg Noise: -87dBm Beacon Interval: 100ms R2 2.4 GHzCh: 13 (2472 MHz) Pwr-Lvl (8 ≤ 15): 8 dBm Radio-Type: IEEE 802.11gn W.: 20 MHz Max-W: 20 MHz Bond.: No Ch-Plan: 4-Channel Plan DCS: active DCS Threshold: -80 dBm Ch Busy Ø: 3% Rx Frames Ø: 2% AP Tx Ø: 0% MBR: 12 MBit/s Avg Noise: -83dBm Beacon Interval: 100ms WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 2 / 161 / 214 |
| ||||||||||||||||||||||||
![]()
Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Nordbau IGNORE_A_WIDTH / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
Name: AP-Inv42-Nordbau-HS10-Empore Hardware: AP3825i Serial Number: 17481186085N0000 Uptime: 01:46:22 h Last succ. Poll: 09.05.2025 07:34:15 Basic PwrUsage: 5900mW SavedEnergy: 46.505,52 Wh (since: 24.08.2022 23:14:01) IP: 172.19.174.224 eth0: d8:84:66:e3:4b:6f eth0 In Errors: 0 SW Version: 09.21.20.0001 Home-Controller: GZ Active/Backup-Ctrl: GZ / UdL6 Poll-Timeout: 4s R1 5.0 GHzCh: 100+1 (5500 MHz) Pwr-Lvl (8 ≤ 16): 16 dBm Radio-Type: IEEE 802.11ac W.: 40 MHz Max-W: 40 MHz Bond.: Yes Ch-Plan: All Channels DCS: active DCS Threshold: -86 dBm Ch Busy Ø: 1% Rx Frames Ø: 0% AP Tx Ø: 0% MBR: 12 MBit/s Avg Noise: -90dBm Beacon Interval: 100ms R2 2.4 GHzCh: 13 (2472 MHz) Pwr-Lvl (8 ≤ 14): 8 dBm Radio-Type: IEEE 802.11gn W.: 20 MHz Max-W: 20 MHz Bond.: No Ch-Plan: 4-Channel Plan DCS: active DCS Threshold: -80 dBm Ch Busy Ø: 3% Rx Frames Ø: 2% AP Tx Ø: 0% MBR: 12 MBit/s Avg Noise: -85dBm Beacon Interval: 100ms WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 2 / 134 / 185 |
| ||||||||||||||||||||||||
![]()
Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Nordbau IGNORE_A_WIDTH / IGNORE_ZERO_TX_ON_A |
Hilfe - Aktualisierungsintervall: 5 Minuten
Version 12.5.6, syj, 17.04.2025
Datenerhebung: 09.05.2025 07:34:01 Erzeugt: 09.05.2025 07:36:25 PID 564659