Name: AP-Inv42-Neubau-312 Hardware: AP310i Serial Number: 2038Y-1364000000 Uptime: 17:31:53 h Last succ. Poll: 21.11.2024 23:20:16 Basic PwrUsage: 5700mW SavedEnergy: 31.282,1 Wh (since: 25.08.2022 00:14:02) IP: 172.19.174.177 eth0: 20:9e:f7:77:2c:46 eth0 In Errors: 0 SW Version: 7.8.6.0-002R Home-Controller: ECA-UdL6 Active/Backup-Ctrl: ECA-UdL6 / ECA-GZ Poll-Timeout: 3s R1 5.0 GHzCh: 108 (5540 MHz) Pwr-Lvl : 18 dBm Radio-Type: IEEE 802.11ax W.: 40 MHz Max-W: 40 MHz Bond.: Yes DCS: monitor Ch Busy Ø: 1% Rx Frames Ø: 0% AP Tx Ø: 1% MBR: 6 MBit/s Avg Noise: -90dBm Beacon Interval: 100ms R2 2.4 GHzCh: 9 (2452 MHz) Pwr-Lvl : 12 dBm Radio-Type: IEEE 802.11ax W.: 20 MHz Max-W: 20 MHz Bond.: No DCS: monitor Ch Busy Ø: 4% Rx Frames Ø: 1% AP Tx Ø: 1% MBR: 6 MBit/s Avg Noise: -100dBm Beacon Interval: 100ms WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 7 / 46 / 60 |
| ||||||||||||||||||||||||
Connected to: Inv42-Neub-211 e 1/1/45 Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Mittelbau ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
Name: AP-Inv42-Nordbau-HS10-Beamer Hardware: AP3825i Serial Number: 16360743085M0000 device unreachable probably powered off due to energy saving Last succ. Poll: 21.11.2024 23:10:09 Basic PwrUsage: 6600mW SavedEnergy: 39.383,91 Wh (since: 25.08.2022 01:49:01) IP: 172.19.174.225 eth0: d8:84:66:74:ee:5f SW Version: 09.21.20.0001 Home-Controller: GZ WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 115 / 213 / 275 |
| ||||||||||||||||||||||||
Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Nordbau ENERGY_SAVING_ENABLED / IGNORE_A_WIDTH / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
Name: AP-Inv42-R1225 Hardware: AP310i Serial Number: 2037Y-1057700000 Uptime: 17:31:52 h Last succ. Poll: 21.11.2024 23:20:16 Basic PwrUsage: 5800mW SavedEnergy: 21.078,17 Wh (since: 14.09.2022 22:14:02) IP: 172.19.174.196 eth0: 20:9e:f7:76:f7:6c eth0 In Errors: 0 SW Version: 7.8.6.0-002R Home-Controller: ECA-GZ Active/Backup-Ctrl: ECA-GZ / ECA-UdL6 Poll-Timeout: 3s R1 5.0 GHzCh: 132 (5660 MHz) Pwr-Lvl : 18 dBm Radio-Type: IEEE 802.11ax W.: 40 MHz Max-W: 40 MHz Bond.: Yes DCS: monitor Ch Busy Ø: 3% Rx Frames Ø: 1% AP Tx Ø: 1% MBR: 6 MBit/s Avg Noise: -91dBm Beacon Interval: 100ms R2 2.4 GHzCh: 13 (2472 MHz) Pwr-Lvl : 12 dBm Radio-Type: IEEE 802.11ax W.: 20 MHz Max-W: 20 MHz Bond.: No DCS: monitor Ch Busy Ø: 17% Rx Frames Ø: 10% AP Tx Ø: 1% MBR: 6 MBit/s Avg Noise: -99dBm Beacon Interval: 100ms WLAN-Sessions: 2 (R2: 2) 2.4n: 2 valid/invalid/unknown IPs: 2 / 0 / 0 auth/not auth Clients: 2 / - Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 10 / 43 / 55 |
| ||||||||||||||||||||||||
Connected to: Inv42-R1225 ge.1.10 Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Hauptgebäude ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
Name: AP-Inv42-Nordbau-3009 Hardware: AP310i Serial Number: 2037Y-1060400000 device unreachable probably powered off due to energy saving Last succ. Poll: 21.11.2024 22:09:48 Basic PwrUsage: 5900mW SavedEnergy: 36.373,64 Wh (since: 14.09.2022 23:14:02) IP: 172.19.174.200 eth0: 20:9e:f7:76:f7:f3 SW Version: 7.8.6.0-002R Home-Controller: ECA-UdL6 WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 17 / 184 / 198 |
| ||||||||||||||||||||||||
Controller Site: Invalidenstr Connected to: Inv42-Nordbau-3024 e 1/1/2 Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Nordbau ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
Name: AP-Inv42-Nordbau-HS10-Empore Hardware: AP3825i Serial Number: 17481186085N0000 device unreachable probably powered off due to energy saving Last succ. Poll: 21.11.2024 22:09:48 Basic PwrUsage: 5900mW SavedEnergy: 38.501,28 Wh (since: 24.08.2022 23:14:01) IP: 172.19.174.224 eth0: d8:84:66:e3:4b:6f SW Version: 09.21.20.0001 Home-Controller: GZ WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 65 / 211 / 228 |
| ||||||||||||||||||||||||
Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Nordbau ENERGY_SAVING_ENABLED / IGNORE_A_WIDTH / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
Name: AP-Inv42-R1124-Flur Hardware: AP310i Serial Number: 2037Y-1074400000 device unreachable probably powered off due to energy saving Last succ. Poll: 21.11.2024 22:09:48 Basic PwrUsage: 6200mW SavedEnergy: 37.615,66 Wh (since: 28.09.2022 22:14:01) IP: 172.19.174.128 eth0: 20:9e:f7:76:fa:af SW Version: 7.8.6.0-002R Home-Controller: ECA-GZ WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 4 / 62 / 62 |
| ||||||||||||||||||||||||
Connected to: Inv42-HG-1133b ge.1.43 Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Hauptgebäude ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A |
Hilfe - Aktualisierungsintervall: 5 Minuten
Version 12.5.4, syj, 05.11.2024
Datenerhebung: 21.11.2024 23:19:01 Erzeugt: 21.11.2024 23:21:41 PID 1266412