? Zielgruppen ?
?

Humboldt-Universität zu Berlin - Computer- und Medienservice

WLAN-Status 02.02.2025 04:06:57

Access Points mit mehr als 100 Sessions innerhalb der vergangenen 7 Tage

Berlin-Mitte, Campus Nord
Name: AP-Ph13-Haus13-Seminarraum
Hardware: AP3805i
Serial Number: 16381523085M0000
Uptime: 36 d 15:34:58 h
Last succ. Poll: 02.02.2025 04:05:36
IP: 172.19.170.28
eth0: d8:84:66:75:07:c1
SW Version: 09.21.20.0001
Home-Controller: UdL6
Active/Backup-Ctrl: UdL6 / GZ
Poll-Timeout: 4s
R1 5.0 GHzCh: 112-1 (5560 MHz)
  Pwr-Lvl (5 ≤ 17): 17 dBm
  Radio-Type:  IEEE 802.11ac
  W.: 40 MHz Max-W: 40 MHz Bond.: Yes
  Ch-Plan: All Channels
  DCS: active
  DCS Threshold: -80 dBm
  AP Tx Ø: 1% MBR: 6 MBit/s
  Avg Noise: -89dBm
  Beacon Interval: 100ms
R2 2.4 GHzCh: 5 (2432 MHz)
  Pwr-Lvl (5 ≤ 18): 18 dBm
  Radio-Type:  IEEE 802.11gn
  W.: 20 MHz Max-W: 20 MHz Bond.: No
  Ch-Plan: 4-Channel Plan
  DCS: active
  DCS Threshold: -80 dBm
  AP Tx Ø: 1% MBR: 6 MBit/s
  Avg Noise: -90dBm
  Beacon Interval: 100ms
WLAN-Sessions: 1  (R2: 1)
  Accs: HU: 1
  2.4n: 1
valid/invalid/unknown IPs: 1 / 0 / 0
auth/not auth Clients: 1 / -
  Min (1d / 7d / 28d): 0 / 0 / 0
  Max (1d / 7d / 28d): 78 / 116 / 116
IndexRadio / BandIf-MACStatusSSIDSessions
1Radio1 5 GHzd8:84:66:6c:80:00Upeduroam
11Radio2 2.4 GHzd8:84:66:6c:80:08Upeduroam1
15Radio2 2.4 GHzd8:84:66:6c:80:0cUp_Free_Wifi_Berlin

SNMP Instanzen UdL6AP: 717 Radio 1: 6729 Radio 2: 6730
SNMP Instanzen GZAP: 962 Radio 1: 8689 Radio 2: 8690
Location:  Berlin-Mitte, Campus Nord > Luisenstr./Philippstr. > Haus 13
IGNORE_ZERO_TX_ON_A
Name: AP-Hann7-Schinkelsaal
Hardware: AP505i
Serial Number: 1916W-2376600000
device unreachable
probably powered off due to energy saving
Last succ. Poll: 01.02.2025 21:09:12
Basic PwrUsage: 8500mW
SavedEnergy: 24.608,18 Wh (since: 20.03.2024 21:14:01)
IP: 172.19.178.144
eth0: dc:b8:08:c2:ef:eb
SW Version: 7.8.6.0-002R
Home-Controller: ECA-UdL6
WLAN-Sessions: 0  
  Min (1d / 7d / 28d): 0 / 0 / 0
  Max (1d / 7d / 28d): 3 / 253 / 275

SNMP Instanzen ECA-GZAP: 539 Radio 1: 5306 Radio 2: 5305
Controller Site: Hann6-7
Connected to: ICX-Hann7-022 e 1/1/12
Location:  Berlin-Mitte, Campus Nord > Hannoversche Str. 7, Mensa Nord
ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A
Name: AP-Hann7-EG-2
Hardware: AP505i
Serial Number: 1916W-2373400000
device unreachable
probably powered off due to energy saving
Last succ. Poll: 01.02.2025 21:09:12
Basic PwrUsage: 8400mW
SavedEnergy: 24.091,80 Wh (since: 20.03.2024 21:14:01)
IP: 172.19.178.182
eth0: dc:b8:08:c2:ef:4b
SW Version: 7.8.6.0-002R
Home-Controller: ECA-UdL6
WLAN-Sessions: 0  
  Min (1d / 7d / 28d): 0 / 0 / 0
  Max (1d / 7d / 28d): 0 / 205 / 270

SNMP Instanzen ECA-GZAP: 541 Radio 1: 5322 Radio 2: 5321
Description: Sud
Controller Site: Hann6-7
Connected to: ICX-Hann7-022 e 1/1/11
Location:  Berlin-Mitte, Campus Nord > Hannoversche Str. 7, Mensa Nord
ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A
Name: AP-Inv42-Nordbau-HS10-Beamer
Hardware: AP3825i
Serial Number: 16360743085M0000
device unreachable
probably powered off due to energy saving
Last succ. Poll: 01.02.2025 23:10:13
Basic PwrUsage: 6200mW
SavedEnergy: 42.992,5 Wh (since: 25.08.2022 01:49:01)
IP: 172.19.174.225
eth0: d8:84:66:74:ee:5f
SW Version: 09.21.20.0001
Home-Controller: GZ
WLAN-Sessions: 0  
  Min (1d / 7d / 28d): 0 / 0 / 0
  Max (1d / 7d / 28d): 2 / 178 / 242

SNMP Instanzen GZAP: 12 Radio 1: 1089 Radio 2: 1090
Connected to: Inv42-Nordbau-3024 e 1/1/4
Location:  Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Nordbau
ENERGY_SAVING_ENABLED / IGNORE_A_WIDTH / IGNORE_ZERO_TX_ON_A
Name: AP-Ph13-Haus9-2115
Hardware: AP3805i
Serial Number: 15431811085H0000
device unreachable
probably powered off due to energy saving
Last succ. Poll: 01.02.2025 23:10:13
Basic PwrUsage: 3100mW
SavedEnergy: 19.891,15 Wh (since: 24.08.2022 23:14:01)
IP: 172.19.170.105
eth0: d8:84:66:31:d2:b8
SW Version: 09.21.20.0001
Home-Controller: UdL6
WLAN-Sessions: 0  
  Min (1d / 7d / 28d): 0 / 0 / 0
  Max (1d / 7d / 28d): 2 / 109 / 110

SNMP Instanzen GZAP: 433 Radio 1: 4457 Radio 2: 4458
Connected to: ICX-Ph13-H9-2111 e 1/1/12
Location:  Berlin-Mitte, Campus Nord > Luisenstr./Philippstr. > Haus 9
ENERGY_SAVING_ENABLED / IGNORE_A_WIDTH / IGNORE_ZERO_TX_ON_A
Name: AP-Hess2-Fischer-HS
Hardware: AP505i
Serial Number: 2023W-2003400000
device unreachable
probably powered off due to energy saving
Last succ. Poll: 01.02.2025 23:10:13
Basic PwrUsage: 8500mW
SavedEnergy: 46.947,39 Wh (since: 11.01.2023 23:14:02)
IP: 172.19.178.180
eth0: dc:b8:08:f2:76:27
SW Version: 7.8.6.0-002R
Home-Controller: ECA-UdL6
WLAN-Sessions: 0  
  Min (1d / 7d / 28d): 0 / 0 / 0
  Max (1d / 7d / 28d): 5 / 198 / 265

SNMP Instanzen ECA-GZAP: 887 Radio 1: 8090 Radio 2: 8089
Controller Site: Hess2
Connected to: B5-He2-022 ge.1.39
Location:  Berlin-Mitte, Campus Nord > Hessische Str. 2
ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A
Name: AP-Ph13-HSZ-AudimaxII-DV-li
Hardware: AP505i
Serial Number: 2023W-2058400000
device unreachable
probably powered off due to energy saving
Last succ. Poll: 01.02.2025 22:09:44
Basic PwrUsage: 8300mW
SavedEnergy: 34.314,34 Wh (since: 16.12.2022 21:39:01)
IP: 172.19.170.191
eth0: dc:b8:08:f2:80:e5
SW Version: 7.8.6.0-002R
Home-Controller: ECA-UdL6
WLAN-Sessions: 0  
  Min (1d / 7d / 28d): 0 / 0 / 0
  Max (1d / 7d / 28d): 18 / 210 / 261

SNMP Instanzen ECA-GZAP: 395 Radio 1: 4154 Radio 2: 4153
Description: HoerSaalZelt Audimax II, Datenverteiler, links
Controller Site: CN_AMII
Connected to: ICX-Ph13-Audimax-temp e 1/1/21
Location:  Berlin-Mitte, Campus Nord > Luisenstr./Philippstr. > Hörsaalzelt-AudimaxII
ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A
Name: AP-Hann7-EG-1
Hardware: AP505i
Serial Number: 1916W-2372200000
device unreachable
probably powered off due to energy saving
Last succ. Poll: 01.02.2025 21:09:12
Basic PwrUsage: 8600mW
SavedEnergy: 24.876,0 Wh (since: 20.03.2024 21:14:01)
IP: 172.19.178.172
eth0: dc:b8:08:c2:ef:0f
SW Version: 7.8.6.0-002R
Home-Controller: ECA-UdL6
WLAN-Sessions: 0  
  Min (1d / 7d / 28d): 0 / 0 / 0
  Max (1d / 7d / 28d): 2 / 250 / 307

SNMP Instanzen ECA-GZAP: 540 Radio 1: 5314 Radio 2: 5313
Description: Nord
Controller Site: Hann6-7
Connected to: ICX-Hann7-022 e 1/1/10
Location:  Berlin-Mitte, Campus Nord > Hannoversche Str. 7, Mensa Nord
ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A


Hilfe - Aktualisierungsintervall: 5 Minuten
Version 12.5.4, syj, 05.11.2024
Datenerhebung: 02.02.2025 04:04:01 Erzeugt: 02.02.2025 04:06:57 PID 215974