WLAN-Status 31.01.2025 07:10:49
Access Points mit 11 bis 25 Sessions innerhalb der vergangenen 4 Wochen
Berlin-Mitte > Georgenstr. 36
Name: AP-Georg36-504 Hardware: AP310i Serial Number: 2038Y-1407500000 Uptime: 01:18:07 h Last succ. Poll: 31.01.2025 07:09:12 Basic PwrUsage: 6000mW SavedEnergy: 40.099,69 Wh (since: 24.08.2022 23:14:01) IP: 172.19.182.148 eth0: 20:9e:f7:77:34:c5 eth0 In Errors: 0 SW Version: 7.8.6.0-002R Home-Controller: ECA-ESZ Active/Backup-Ctrl: ECA-ESZ / ECA-JvN Poll-Timeout: 3s R1 5.0 GHzCh: 100 (5500 MHz) Pwr-Lvl : 18 dBm Radio-Type: IEEE 802.11ax W.: 80 MHz Max-W: 80 MHz Bond.: Yes DCS: monitor Ch Busy Ø: 4% Rx Frames Ø: 1% AP Tx Ø: 1% MBR: 6 MBit/s Avg Noise: -88dBm Beacon Interval: 100ms R2 2.4 GHzCh: 13 (2472 MHz) Pwr-Lvl : 12 dBm Radio-Type: IEEE 802.11ax W.: 20 MHz Max-W: 20 MHz Bond.: No DCS: monitor Ch Busy Ø: 6% Rx Frames Ø: 1% AP Tx Ø: 1% MBR: 6 MBit/s Avg Noise: -98dBm Beacon Interval: 100ms WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 4 / 7 / 16 |
| ||||||||||||||||||||||||
Connected to: ICX-Georg36-421 e 1/1/5 Location: Berlin-Mitte > Georgenstr. 36 IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
Name: AP-Georg36-421 Hardware: AP310i Serial Number: 2038Y-1408100000 Uptime: 01:21:20 h Last succ. Poll: 31.01.2025 07:09:12 Basic PwrUsage: 6000mW SavedEnergy: 37.645,1 Wh (since: 24.08.2022 23:14:01) IP: 172.19.182.176 eth0: 20:9e:f7:77:34:e3 eth0 In Errors: 0 SW Version: 7.8.6.0-002R Home-Controller: ECA-JvN Active/Backup-Ctrl: ECA-JvN / ECA-ESZ Poll-Timeout: 3s R1 5.0 GHzCh: 132 (5660 MHz) Pwr-Lvl : 18 dBm Radio-Type: IEEE 802.11ax W.: 80 MHz Max-W: 20 MHz Bond.: Yes DCS: monitor Ch Busy Ø: 3% Rx Frames Ø: 1% AP Tx Ø: 1% MBR: 6 MBit/s Avg Noise: -94dBm Beacon Interval: 100ms R2 2.4 GHzCh: 5 (2432 MHz) Pwr-Lvl : 12 dBm Radio-Type: IEEE 802.11ax W.: 20 MHz Max-W: 20 MHz Bond.: No DCS: monitor Ch Busy Ø: 5% Rx Frames Ø: 1% AP Tx Ø: 2% MBR: 6 MBit/s Avg Noise: -97dBm Beacon Interval: 100ms WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 4 / 11 / 15 |
| ||||||||||||||||||||||||
Connected to: ICX-Georg36-421 e 1/1/1 Location: Berlin-Mitte > Georgenstr. 36 IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
Name: AP-Georg36-514 Hardware: AP310i Serial Number: 2038Y-1389800000 Uptime: 2 d 01:17:41 h Last succ. Poll: 31.01.2025 07:09:12 Basic PwrUsage: 5800mW SavedEnergy: 35.838,77 Wh (since: 25.08.2022 23:14:02) IP: 172.19.182.139 eth0: 20:9e:f7:77:31:50 eth0 In Errors: 0 SW Version: 7.8.6.0-002R Home-Controller: ECA-ESZ Active/Backup-Ctrl: ECA-ESZ / ECA-JvN Poll-Timeout: 3s R1 5.0 GHzCh: 52 (5260 MHz) Pwr-Lvl : 10 dBm Radio-Type: IEEE 802.11ax W.: 80 MHz Max-W: 80 MHz Bond.: Yes DCS: monitor Ch Busy Ø: 5% Rx Frames Ø: 3% AP Tx Ø: 1% MBR: 6 MBit/s Avg Noise: -80dBm Beacon Interval: 100ms R2 2.4 GHzCh: 9 (2452 MHz) Pwr-Lvl : 12 dBm Radio-Type: IEEE 802.11ax W.: 20 MHz Max-W: 20 MHz Bond.: No DCS: monitor Ch Busy Ø: 8% Rx Frames Ø: 1% AP Tx Ø: 1% MBR: 6 MBit/s Avg Noise: -99dBm Beacon Interval: 100ms WLAN-Sessions: 1 (R1: 1) Accs: HU: 1 5.0ax: 1 valid/invalid/unknown IPs: 1 / 0 / 0 auth/not auth Clients: 1 / - Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 12 / 13 / 13 |
| ||||||||||||||||||||||||
Connected to: ICX-Georg36-421 e 1/1/7 Location: Berlin-Mitte > Georgenstr. 36 IGNORE_ZERO_TX_ON_A |